Contact Info:
ECS2 Group Inc.
9-6975 Meadowvale Town
Centre Circle, Suite 322
Mississauga,
Ontario L5N 2V7
Canada
Phone: (905)
593-2345
E-mail us
here.
|
|
|
DCA-31
Intrinsically Safe Data Collector
The DCA-31/IS allows the user to
perform vibration analysis in hazardous areas such as those
commonly found in the petrochemical industry.
Intrinsically Safe
The DCA-31/IS is certified according to ATEX (European
Community) directive 100a for non-mining applications with a
gaseous explosive hazard continuously present ( II1G EEx ia IIC).
IS certification information can be provided upon request. |
Integration
The DCA-31/IS can be integrated with a number of condition
monitoring systems, including ExpertALERT, AdvancedALERT®, DLI
Watchman® DCX™, and DCX Online™ systems. Load or unload your
survey data through its traditional serial port.
Features
Unit includes a single-axis sensor, 6-foot coiled sensor cable,
AC charger cable, PC communications cable, hand strap, and
operating manual.
Selected features include:
Single-channel vibration data acquisition
Tachometer input channel for collection of speed and phase
data
Integrator converts accelerometer data to velocity
Overall (RMS) calculation for integrated or non-integrated
measurements
Enveloping for amplitude demodulation
DC voltage measurement for temperature or process readings
Compact, lightweight design
IP-54 rating for use in harsh environments
6-8 hours battery life using removable 1800 mAh NiMH battery
pack
Ruggedized polycarbonate / ABS case for high impact
resistance and durability
1/8 VGA backlit LCD touchscreen
Easy to use buttons
Intuitive software interface
16 MB on board route memory
Maximum frequency span selectable from 25 Hertz to 40
kilohertz
Complies with CENELEC standards EN50081-2 (emission) and
EN61000-6-2 (susceptibility) for electro-magnetic interference
The DCA-31/IS accepts a variety of sensors, including ICP®
accelerometers*, velocity transducers, displacement probes,
infrared temperature sensors, DC input, or signals from
installed monitoring equipment. Please note that sensors must
also be IS certified for use in hazardous environments.
*ICP® is a registered trademark of PCB.
The DCA-31/IS includes a digital signal processing (DSP)
microprocessor that operates at a bandwidth of 40 Khz. This
translates into rapid data processing and averaging so your data
collection is fast and real-time displays do in fact, represent
REAL time.
|
| |
For more info,
please click
here. |
|